Patrik Widstrand
Norway, Denmark & Marine applications
Tel: +46 70-564 82 20
The FNC MT Ø50 has a robust mechanical and electrical construction with a freely programmable measuring range. With its Ø50mm outer diameter it can offer both shaft and end hollow shaft between 6 to 12mm and can give protection up to IP67. 0-10V voltage or 4-20mA current output.
| Electrical ratings | |
| Voltage supply | 10-30 VDC |
| Protection | Output short circuit protection and reverse polarity protection |
| Consumption w/o load | 60 mA (24 VDC) |
| Output signals | 0-10 VDC Voltage output
0-5 VDC Voltage output 4-20 mA current output |
| Measuring range | Up to 65536 revolution |
| Interference immunity | DIN EN 61000-6-2 |
| Emitted interference | DIN EN 61000-6-4 |
| Approval | CE |
| Mechanical design | |
| Dimensions (flange) | ø50 mm (see drawings) |
| Shaft load | 140 N axial
240 N radial |
| Protection DIN EN 60529 | IP54, IP65 |
| Operating speed | 10000 rpm |
| Starting torque | 0.025 Nm (IP 65) |
| Materials | Housing: Aluminium
Flange: Aluminium Shaft: Stainless steel |
| Shaft/Hollow shaft diameter | 6, 8, 10, 12 mm
(other diameters on request) |
| Bearings lifetime | 2x10 rev. At 100% of full rated shaft load (minimum) |
| Operating temperature | -20…+85°C |
| Storage temperature | -30°C…+90°C |
| Weight approx | 250 g |


Industrial • Medicine technology
0-10V • 0-5V • 4-20mA • IP67 • Magnetic • Optical • Programmable
The FNC MT Ø50 has a robust mechanical and electrical construction with a freely programmable measuring range. With its Ø50mm outer diameter it can offer both shaft and end hollow shaft between 6 to 12mm and can give protection up to IP67. 0-10V voltage or 4-20mA current output.
| Electrical ratings | |
| Voltage supply | 10-30 VDC |
| Protection | Output short circuit protection and reverse polarity protection |
| Consumption w/o load | 60 mA (24 VDC) |
| Output signals | 0-10 VDC Voltage output
0-5 VDC Voltage output 4-20 mA current output |
| Measuring range | Up to 65536 revolution |
| Interference immunity | DIN EN 61000-6-2 |
| Emitted interference | DIN EN 61000-6-4 |
| Approval | CE |
| Mechanical design | |
| Dimensions (flange) | ø50 mm (see drawings) |
| Shaft load | 140 N axial
240 N radial |
| Protection DIN EN 60529 | IP54, IP65 |
| Operating speed | 10000 rpm |
| Starting torque | 0.025 Nm (IP 65) |
| Materials | Housing: Aluminium
Flange: Aluminium Shaft: Stainless steel |
| Shaft/Hollow shaft diameter | 6, 8, 10, 12 mm
(other diameters on request) |
| Bearings lifetime | 2x10 rev. At 100% of full rated shaft load (minimum) |
| Operating temperature | -20…+85°C |
| Storage temperature | -30°C…+90°C |
| Weight approx | 250 g |


Industrial • Medicine technology