– FNC MBAA44

Rotating absolute analogue encoder with separate magnet

Info
Ladda ner

The MBAA series offers non-contact measurement via a stand-alone magnet in rotating applications for speed and position control such as angle, length and inclination.

Thanks to the non-contact technology, without wear parts, long life is achieved even in the toughest applications.

Technical data

Electrical ratings
Voltage supply4.75VDC to 30VDC
4.75VDC to 5.5VDC
ProtectionOutput short circuit protection
Reverse polarity protection
(except 5V version)
Consumption w/o load<60 mA (24VDC)
Output signals0-10VDC Voltage output
1-5VDC Voltage output
4-20mA current output
Output frequency>200kHz
Output signals90° shifted A and B, Z + inverted
Output circuitLinedriver/RS422
Push-pull short-circuit proof
NPN Open Collector
Interference immunityDIN EN 61000-6-2
Emitted interferenceDIN EN 61000-6-4
ApprovalCE
Mechanical design
DimensionsØ44-58 mm
Protection DIN EN 60529IP54, IP65
Operating speed<10000 rpm
Starting torque<0.025 Nm (IP67)
MaterialsAluminium
Magnet optionsMHB10AA, MHB10625, MHM04
Operating temperature-20°C up to +85°C
Storage temperature-40°C up to +85°C
Weight approx.110g

Det finns ännu inga filer att ladda ner.

Allmän info


Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 2

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 2

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 3

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 3

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 4

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 4

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 5

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 5

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 6

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 6

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 7

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 7
Fabrikat

Kategori

Typ

Montage

Tillämpning

Övrigt

Fråga oss

The MBAA series offers non-contact measurement via a stand-alone magnet in rotating applications for speed and position control such as angle, length and inclination.

Thanks to the non-contact technology, without wear parts, long life is achieved even in the toughest applications.

Technical data

Electrical ratings
Voltage supply4.75VDC to 30VDC
4.75VDC to 5.5VDC
ProtectionOutput short circuit protection
Reverse polarity protection
(except 5V version)
Consumption w/o load<60 mA (24VDC)
Output signals0-10VDC Voltage output
1-5VDC Voltage output
4-20mA current output
Output frequency>200kHz
Output signals90° shifted A and B, Z + inverted
Output circuitLinedriver/RS422
Push-pull short-circuit proof
NPN Open Collector
Interference immunityDIN EN 61000-6-2
Emitted interferenceDIN EN 61000-6-4
ApprovalCE
Mechanical design
DimensionsØ44-58 mm
Protection DIN EN 60529IP54, IP65
Operating speed<10000 rpm
Starting torque<0.025 Nm (IP67)
MaterialsAluminium
Magnet optionsMHB10AA, MHB10625, MHM04
Operating temperature-20°C up to +85°C
Storage temperature-40°C up to +85°C
Weight approx.110g

General info

Supplier

Category

Product type

Mounting

Application

Attributes

Ask us

Gustav Dyvling

Mid Sweden

P: +46 (0) 790 064 471

Email

Markus Ödlund

Southeast Sweden

P: +46 (8) 121 519 60

Email

Martin Jonsson

Western Sweden & Denmark

P: +46 8-121 519 63

Email

Helena Benjamin

Northern Sweden

P: +46 (0) 8 121 519 62

Email

Niclas Qvist

Key account Sweden

P: +46 (0) 8 121 519 57

Email

searchfacebookglobelinkedininstagramapartmenttagsmartphonebubbleclock