Absolute Encoder (single-turn, ST or multi-turn, MT) with Bus cover that simplifies installation of your own selected cable. Depending on your application and needs, there are a number of different mounting brackets to order. By default, it is possible to configure the sensor with a 6, 8 or 10mm end hollow shaft. If you need other dimensions, please contact us.

Technical data

Electrical ratings 
Voltage supply5.5VDC to 30VDC

 

4.75VDC to 5.5VDC

8VDC to 30VDC

ProtectionOutput short circuit protection

 

Reverse polarity protection

Consumption w/o load50 mA (24 VDC)
Initializing time typ.170 ms after power on
InterfaceProfibus/CANopen
Resolution (steps/turn)9 to 19 bit
Number of revolutionUp to 32 bit
CodeBinary
Code sequenceCW default, programmable
Absolute accuracy, magnetic+/-0.35°
Device adressRotary switch in bus cover
Interface immunityDIN EN 61000-6-2
Emitted interferenceDIN EN 61000-6-4
ApprovalCE
Programmable parametersSteps per revolution

 

Number of revolutions

Preset

Scaling

Rotating direction

Diagnostic functionsPosition or parameter error

 

Multiturn sensing

Status indicatorRED&GREEN-LED integrated in bus cover
Mechanical design 
Dimensions (flange)Ø58 mm
Shaft loading140 N axial

 

240 N radial

Protection DIN EN 60529IP54, IP65
Operating speed10000 rpm
Starting torque0.025 Nm (IP 67)
MaterialsHousing: Aluminium

 

Flange: Aluminium

Shaft: Stainless steel

Hollow shaft diameter6, 8 or 10 mm

 

(other diameters on request)

Bearings lifetime2x10 rev. at 100% of full rated shaft load (minimum)
Operating temperatur-25…+90 °C
Weight approx300 g
ConnectionBus cover

Dimensions

FNC AC 58E Bus Cover

Part number code

FNC AC 58E Bus Cover

Det finns ännu inga filer att ladda ner.

Allmän info


Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 2

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 2

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 3

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 3

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 4

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 4

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 5

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 5

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 6

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 6

Warning: Undefined variable $post in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 7

Warning: Attempt to read property "ID" on null in /www/webvol9/7s/dl3w34kejqtj65j/stigab.se/public_html/wp-content/plugins/oxygen/component-framework/components/classes/code-block.class.php(133) : eval()'d code on line 7
Fabrikat

Kategori

Typ

Montage

Tillämpning

Övrigt

Fråga oss

Absolute Encoder (single-turn, ST or multi-turn, MT) with Bus cover that simplifies installation of your own selected cable. Depending on your application and needs, there are a number of different mounting brackets to order. By default, it is possible to configure the sensor with a 6, 8 or 10mm end hollow shaft. If you need other dimensions, please contact us.

Technical data

Electrical ratings 
Voltage supply5.5VDC to 30VDC

 

4.75VDC to 5.5VDC

8VDC to 30VDC

ProtectionOutput short circuit protection

 

Reverse polarity protection

Consumption w/o load50 mA (24 VDC)
Initializing time typ.170 ms after power on
InterfaceProfibus/CANopen
Resolution (steps/turn)9 to 19 bit
Number of revolutionUp to 32 bit
CodeBinary
Code sequenceCW default, programmable
Absolute accuracy, magnetic+/-0.35°
Device adressRotary switch in bus cover
Interface immunityDIN EN 61000-6-2
Emitted interferenceDIN EN 61000-6-4
ApprovalCE
Programmable parametersSteps per revolution

 

Number of revolutions

Preset

Scaling

Rotating direction

Diagnostic functionsPosition or parameter error

 

Multiturn sensing

Status indicatorRED&GREEN-LED integrated in bus cover
Mechanical design 
Dimensions (flange)Ø58 mm
Shaft loading140 N axial

 

240 N radial

Protection DIN EN 60529IP54, IP65
Operating speed10000 rpm
Starting torque0.025 Nm (IP 67)
MaterialsHousing: Aluminium

 

Flange: Aluminium

Shaft: Stainless steel

Hollow shaft diameter6, 8 or 10 mm

 

(other diameters on request)

Bearings lifetime2x10 rev. at 100% of full rated shaft load (minimum)
Operating temperatur-25…+90 °C
Weight approx300 g
ConnectionBus cover

Dimensions

FNC AC 58E Bus Cover

Part number code

FNC AC 58E Bus Cover

General info

Supplier

Category

Product type

Mounting

Application

Attributes

Ask us

Markus Ödlund

Southeast Sweden

P: +46 (8) 121 519 60

Email

Martin Jonsson

Western Sweden & Denmark

P: +46 (0) 702 421 451

Email

Helena Benjamin

Northern and mid Sweden

P: +46 (0) 8 121 519 62

Email

Niclas Qvist

Key account Sweden

P: +46 (0) 8 121 519 57

Email

searchfacebookglobelinkedininstagramapartmenttagsmartphonebubbleclock